Home / Our Projects / Üregen Biogas · Gas Cleaning
Biogas plant · Gas cleaning systems
Üregen Biogas · Gas Cleaning
2 scrubber towers · Gas cleaning
2Scrubber towers


GAS CLEANING PERFORMANCE
At a flow rate of 800 m³/h
H₂S control.
Our two-tower scrubber system at Üregen Biogas Plant reduces the inlet H₂S concentration of 12,000 ppm to 0 ppm at a biogas flow rate of 800 m³/h.
BIOGAS FLOW RATE800 m³/h
INLET H₂S12,000 ppm
OUTLET H₂S0 ppm
PROJECT INFORMATION
Project overview.
| Project name | Üregen Biogas · Gas Cleaning |
|---|---|
| Plant type | Biogas plant |
| Service scope | Gas cleaning system |
| Number of scrubber towers | 2 units |
| Biogas flow rate | 800 m³/h |
| Inlet H₂S | 12,000 ppm |
| Outlet H₂S | 0 ppm |
ÜREGEN / FIELD MEASUREMENT RECORDS
The analyser readings show
a reduction in H₂S.
The supplied before-and-after measurement photographs show H₂S concentration decreasing from 17,311 ppm to 522 ppm.
This section presents the photographed measurement record. The separately reported project performance of 12,000 → 0 ppm at 800 m³/h is presented above.
Contact us for information about our gas cleaning projects at biogas and landfill gas plants.
Our Gas Cleaning Solutions ↗Let’s discuss this project.
Contact us about this plant or a similar investment.